JP Series Replacing LEF Series While Using Existing Wiring

You are here:
Estimated reading time: 1 min

Using existing LEF wire (22AWG, shielded) in place of the recommended JP wiring (CAT5e/6 -monitors, 18-AWG, Unshielded – doors) will function within the specified distances below.

 

Aiphone 8222xx series wire = 22AWG, shielded

  • Using 822203 series wire or equivalent will allow a JK/JP series door station to work up to 165 feet to the JP-4MED Master Station.
  • Using 8222xx series wire or equivalent will allow the JP system to work up to 330 feet from the JP-MED to the farthest JP-4HD.

Between inside stations, the JP series requires 8 conductors.

Between the door station and JP-4MED Master Station: 2 conductors are required for audio and video. A separate pair of wires will be required for door release if it is included.

 

DISCLAIMER: Shielded wire has been tested and approved at the distances shown below. However, if technical difficulties or video image degradation occurs, it will be the responsibility of the installing contractor to replace the cable with the specified cable.