AX Series

banner
Application Notes
AX Series with Viking K-1900-5 and RC-2A for CO Line Transfer and Door Release
custom-icon
Summary The Viking K-1900-5 is used for the CO Line Transfer mode, transferring a door station call to a programmed telephone number. With communication established on the phone line, the Viking RC-2A allows the telephone to trigger a single door release contact.   Wiring Diagram Max. distance from each… Read More
Mantrip Wiring and Configuration
custom-icon
AX Series – Mantrap Wiring and Configuration
Common Issues
AX Central Exchange Unit Power LED Flashing
custom-icon
Summary The power LED flashes on an AX Central Exchange Unit.   Cause Incorrect programming in the AX Setup Software can cause the LED to flash.   Solution Check the program settings for the Central Exchange Unit. If there is not an add-on exchange (AX-320C), make sure the program setting… Read More
Door Station Lens Damage Recommendation
custom-icon
Summary  When an Aiphone AX-DV or AX-DVF door station lens gets scratched, there are a few options to repair it.    Solution  If the lens on the video door station gets scratched, we recommend using Novus Plastic Polish Kit… Read More
No Video Output on AX CEU During CO Line Communication
custom-icon
Summary No video output on an AX Central Exchange Unit during CO line communication.   Cause When a door station establishes communication through the CO output, it occupies a talk path, but no video is present at the respective video output… Read More
Modifications
AX Series Open Collector Output
custom-icon
Summary The AX-084C and AX-248C have open collector outputs to trigger a recording device when there is a video signal present on the V1 and V2 video outputs. The open collector outputs labeled VCH1 and VCH2 can be used in conjunction with the RY-24L relay. The diagram below shows this… Read More
AX-DV External Switch Modification
custom-icon
Summary Add two wires to AX-DV to allow an external switch to activate the call-in circuit.   Instructions Remove the front cover of AX-DV by removing the security screw on the bottom of the unit. Remove the back cover by removing the single screw on the back of the unit. Read More
Specifications
AX-A Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor Wiring Distance 980′ Mounting Surface mount directly to the wall Dimensions 7-1/16″ H x 5-⅝” W x 2-3/16″ D… Read More
RY-1824L Technical Specifications
custom-icon
Line Drawing   Specifications Features Normally open (N/O) contact with a high current rating for door strikes Normally closed (N/C) contact with high current for magnetic locks Use with any 18-24V system that requires door release Power Source Supplied by Master Station or CEU Contact Rating 250V AC, 8A… Read More
RY-ES Technical Specifications
custom-icon
Line Drawing   Specifications Features Allows an external device to be triggered when the intercom is called External device will be activated when the door station calls in Power Source 12-24V DC, 12-16V AC – supplied by Master Station Contact Rating 125V AC, 1.0A 30V DC, 1.0A Compatible Stations… Read More
MCW-S/B Technical Specifications
custom-icon
Line Drawing   Specifications Features Allows desk mounting of master and / or handset station Mounting hardware included Station is propped up for easier viewing Pre-drilled mounting holes Constructed with sturdy ABS plastic Adjustable to 45° or 60° angles Compatible Stations AX-8M, AX-8MV, AX-8MV-W, DB-1MD, DB-1SD, GT-1A, GT-1C7, GT-1M3,… Read More
SBX-ACE Technical Specifications
custom-icon
Line Drawing   Specifications Features Weather resistant Includes space inside for wiring Mounts to 1-gang box or ring Can mount directly to wall surface Material 18 gauge polished stainless steel Mounting Surface mount directly to the wall or 1-gang box Overall Dimensions 7-1⁄16″ H x 9-⅛” W x 4-¼”… Read More
KMB-45 Technical Specifications
custom-icon
Line Drawing   Specifications Features 45˚ Mullion Mounting Bracket for C-D, GT-D, IF-DA, IX-BA, IX-DA, JO-DA, JP-DA, KB-DAR, KB-DAR-M, or LE-D Can mount to either right or left of the door Mounting Surface mount directly to the wall or mullion Dimensions 5-1/2” H x 5-1/2” W… Read More
KAW-D Technical Specifications
custom-icon
Line Drawing Specifications Features Provides a better viewing angle for the camera Compatible with Aiphone 1-gang surface mount door stations Angles 1-gang door stations outward by 30° Can mount to either right or left of door Hinged cover for mounting door station Material ABS Plastic Mounting Surface mount directly… Read More
AC-10S Technical Specifications (Discontinued)
custom-icon
Line Drawing   Specifications Power Source 12-24V AC or DC Current Consumption AC: 100mA (max.) DC: 70mA (max.) Number of Relays 2 Relay Contact Capacity 24V DC, 3A (resistive load) 1A (inductive load) 24V AC, 3A (resistive load) 1A (inductive load) Mounting Surface wall mount Protection Rating IP54 Operating… Read More
AXW-PA Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Exchange Unit or Master Station Input Direct Central Exchange Unit connection Output 600Ω Output to Adaptor 0dB and -20dB, selectable Requirements AUX input (10kΩ) or 100mV for rated output Wiring 2-cond., overall shield — use Aiphone #822202 Wiring Distance 980′… Read More
AXW-AZ Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Exchange Unit Video Input & Output 75Ω composite video, 1V p-p Video Connectors BNC Video Monitoring 30 sec., controlled by Master Station Camera Activation N/C sensor input, or by Master Station Wiring Cat-5e, 24AWG UTP-4 Wiring Distance AXW-AZ to Central Exchange… Read More
AXW-AVR Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Exchange Unit Video Input & Output Composite 1V Peak-to-Peak, NTSC Video Connectors BNC CEU Input RJ-45 Door Release Contact Normally Open contact output; 30V DC, 1A Wiring Cat-5e, 24AWG UTP-4 Wiring Distance AXW-AVR to Central Exchange Unit (cumulative): max. 980′ AXW-AVR… Read More
AXW-AVT Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC, 500mA supplied by PS-2420UL Video Input & Output Composite 1V Peak-to-Peak, NTSC Video Connectors BNC Door Input RJ-45 Door Release Contact Normally Open contact output; 30V DC, 1A Sensor Normally Closed contact input Wiring Cat-5e, 24AWG UTP-4 Wiring Distance AXW-AVT to Door:… Read More
AX-BN Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor Wiring Distance 980′ Mounting Semi-flush mount Dimensions 8-3/16″ H x 6″ W x 1-15/16″ D Additional Features Privacy button… Read More
AX-B Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor Wiring Distance 980′ Mounting Semi-flush mount Dimensions 8-3/16″ H x 6″ W x 1-15/16″ D… Read More
AX-AN Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor Wiring Distance 980′ Mounting Surface mount directly to the wall Dimensions 7-1/16″ H x 5-⅝” W x 2-3/16″ D Additional Features Privacy button… Read More
AX-8M Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC Supplied by AX CEU Communication Hands-free Headset Jack 3.5mm microphone and speaker jacks Calling Capacity Up to 7 additional master stations Up to 120 door / sub stations Wiring CAT5e/6 homerun to CEU Wiring Distance 330′ Mounting Desk or Surface wall… Read More
AX-DVF-P Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Camera 1/4″ CCD Camera Angle Area View: 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Card Reader HID® ProxPoint® Plus reader (6005B) Minimum Illumination 5 lux Wiring Door Station to Central Exchange Unit: Cat-5e Wiring… Read More
AX-DVF Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Camera 1/4″ CCD Camera Angle Area View: 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Wiring Door Station to Central Exchange Unit: Cat-5e Wiring Distance 980′ Mounting Flush mount or surface… Read More
AX-DV-P Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Camera 1/4″ CCD Camera Angle Area View: 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Card Reader HID® ProxPoint® Plus (6005B) Minimum Illumination 5 lux Wiring Door Station to Central Exchange Unit: Cat-5e Wiring Distance… Read More
AX-DV Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by AX Central Exchange Unit Communication Hands-free Camera 1/4″ CCD Camera Angle Area View: 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Wiring Door Station to Central Exchange Unit: Cat-5e Wiring Distance 980′ Mounting Surface wall mount Operating… Read More
AX-320C Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC, 2A. PS-2420UL (1 for an audio-only system,2 for audio/video system) Current Consumption Maximum 400mA Door Release Contact 24V AC/DC, 500mA Station Capacity 32 door/sub stations per add-on unit Wiring RJ45 plugs for CAT-5e homerun wire runs from each master and door/sub… Read More
AX-248C Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC, 2A. PS-2420UL (1 for an audio-only system,2 for audio/video system) Current Consumption Maximum 3.2A Door Release Contact 24V AC/DC, 500mA Station Capacity 8 master stations, 24 door/sub stations Wiring RJ45 plugs for CAT-5e homerun wire runs from each master and door/sub… Read More
IE-SSR Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from Central exchange unit or Master Station Communication Open voice hands-free communication Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor, PE insulation, Aiphone wire #822202 when not using Central exchange unit Wiring Distance 980′(Cat-5e with AX Series) 1,180′(18′ AWG) 500′(22… Read More
IE-SS/A Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from Central exchange unit or Master Station Communication Open voice hands-free communication Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor, PE insulation, Aiphone wire #822202 when not using Central exchange unit Wiring Distance 980′(Cat-5e with AX Series) 1,180′(18′ AWG) 500′(22… Read More
IE-JA Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from Central exchange unit or Master Station Communication Open voice hands-free communication Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor, PE insulation, Aiphone wire #871802 when not using Central exchange unit Wiring Distance 980′(18 AWG with AX Series) 1,180′(18′ AWG)… Read More
IF-DA Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from Central exchange unit or Master Station Communication Open voice hands-free communication Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor, PE insulation, Aiphone wire #871802 when not using Central exchange unit Wiring Distance 980′(18 AWG with AX Series) 1,180′(18′ AWG)… Read More
AX-DM Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from Central exchange unit Communication Open voice hands-free communication (auto voice actuation or PTT controlled by Master Station) Wiring Door Station to Central Exchange Unit: Cat-5e or 2-conductor, PE insulation, Aiphone wire #871802 when not using Central exchange unit Wiring Distance 980′(18… Read More
AX-084C Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC, 2A. PS-2420UL (1 for an audio-only system,2 for audio/video system) Current Consumption Video: Maximum 0.62A Audio: Maximum 0.65A Door Release Contact 24V AC/DC, 500mA Station Capacity 4 master stations, 8 door/sub stations Wiring RJ45 plugs for CAT-5e homerun wire runs from each… Read More
AX-16SW Technical Specifications
custom-icon
Line Drawing Specifications Calling Capacity 16 Sub Stations per Unit Wiring By two junction connectors (supplied) plugged to each Master AX-8M or AX-8MV, and to next add-on selector AX-16SW. Mounting Desk or Surface wall mount Operating Temperature 32°~104° F (0° ~ 40° C) Dimensions 6-7⁄8″ x 3-3⁄8″ x 1-7⁄8″… Read More
AX-8MV Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC Supplied by AX CEU Communication Hands-free Screen 3.5″ TFT color LCD Scanning Lines 525 lines Video Output NTSC Standard 1Vpp (0.7-1.4Vpp) Headset Jack 3.5mm microphone and speaker jacks Calling Capacity Up to 7 additional master stations Up to 120 door /… Read More
Tips
Door Station Lens Damage Recommendation
custom-icon
Summary  When an Aiphone AX-DV or AX-DVF door station lens gets scratched, there are a few options to repair it.    Solution  If the lens on the video door station gets scratched, we recommend using Novus Plastic Polish Kit… Read More
No Video Output on AX CEU During CO Line Communication
custom-icon
Summary No video output on an AX Central Exchange Unit during CO line communication.   Cause When a door station establishes communication through the CO output, it occupies a talk path, but no video is present at the respective video output… Read More
Wiring Diagrams
External Signaling with the AX Master Station
custom-icon
Summary Steps on connecting an external signaling device such as a chime or bell to an AX master station.   Solution Follow the diagram below using the 6-pin connector included with the AX master station. Step 1 Connect Brown (V+) and Red (V-) to standard coax monitor / DVR input. Read More
AX Series Open Collector Output
custom-icon
Summary The AX-084C and AX-248C have open collector outputs to trigger a recording device when there is a video signal present on the V1 and V2 video outputs. The open collector outputs labeled VCH1 and VCH2 can be used in conjunction with the RY-24L relay. The diagram below shows this… Read More
AX Series with Viking K-1900-5 and RC-2A for CO Line Transfer and Door Release
custom-icon
Summary The Viking K-1900-5 is used for the CO Line Transfer mode, transferring a door station call to a programmed telephone number. With communication established on the phone line, the Viking RC-2A allows the telephone to trigger a single door release contact.   Wiring Diagram Max. distance from each… Read More

Transform Your Security Today

Connect with our local experts for product questions, demos, and assistance in designing your ideal security solution.

Contact Us

Recent Articles

Stay current with our latest technical resources. We update them regularly to support your evolving security needs.

IXG Series, IXG Series Application Notes
Adding and Removing IXG App Users with the IXG App Portal
IXG Series, Programming
Log Tool for IXG-DM7-HID(A) Instructions
Firmware & Software, IXG Series
IXG-DM7-HID(A) Sub-System Firmware 3.01 (Released 04/21/2025)
Firmware & Software, IXG Series
IXG Support Tool 6.0.0.3 (Released 04/08/2025)