Customize Consent Preferences

We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.

The cookies that are categorized as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. ... 

Always Active

Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.

No cookies to display.

Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.

No cookies to display.

Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.

No cookies to display.

Performance cookies are used to understand and analyze the key performance indexes of the website which helps in delivering a better user experience for the visitors.

No cookies to display.

Advertisement cookies are used to provide visitors with customized advertisements based on the pages you visited previously and to analyze the effectiveness of the ad campaigns.

No cookies to display.

JF Series

banner
Specifications
JBW-BA Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC Current Consumption Maximum 120mA Wire Type 18AWG 2 conductor Wiring Distance JBW-BA to JF Door Station: 330′ (22AWG) or 650′ (18AWG) JBW-BA to Furthest Sub Master Station: 165′ (22AWG and 18AWG) JBW-BA to PS-1820UL Power Supply: 165′ (22AWG and 18AWG) Mounting Surface… Read More
IX-SOFT Technical Specifications
custom-icon
Line Drawing Specifications Features Place and receive calls and pages Monitor door stations 50 programmable speed-dial buttons Call history Call transfer Interactive map Line Supervision Certified for use with Cisco Unified Call Manager® Certified for use with Avaya IP Office™ and Avaya Aura® Certified for use with Acatel-Lucent’s OmniPCX… Read More
RY-1824L Technical Specifications
custom-icon
Line Drawing   Specifications Features Normally open (N/O) contact with a high current rating for door strikes Normally closed (N/C) contact with high current for magnetic locks Use with any 18-24V system that requires door release Power Source Supplied by Master Station or CEU Contact Rating 250V AC, 8A… Read More
RY-ES Technical Specifications
custom-icon
Line Drawing   Specifications Features Allows an external device to be triggered when the intercom is called External device will be activated when the door station calls in Power Source 12-24V DC, 12-16V AC – supplied by Master Station Contact Rating 125V AC, 1.0A 30V DC, 1.0A Compatible Stations… Read More
IER-2 Technical Specifications
custom-icon
Line Drawing   Specifications Features Announces chime tone only Adjustable volume (3 positions) Indoor mounting Compatible Stations Call Extension Speaker for DB Series, JF Series, JK Series, JO Series, JP Series, KB Series, or NIM Series Mounting Surface mount directly to the wall or 1-gang box Dimensions 4-3/4″H x… Read More
MCW-S/B Technical Specifications
custom-icon
Line Drawing   Specifications Features Allows desk mounting of master and / or handset station Mounting hardware included Station is propped up for easier viewing Pre-drilled mounting holes Constructed with sturdy ABS plastic Adjustable to 45° or 60° angles Compatible Stations AX-8M, AX-8MV, AX-8MV-W, DB-1MD, DB-1SD, GT-1A, GT-1C7, GT-1M3,… Read More
SBX-ACE Technical Specifications
custom-icon
Line Drawing   Specifications Features Weather resistant Includes space inside for wiring Mounts to 1-gang box or ring Can mount directly to wall surface Material 18 gauge polished stainless steel Mounting Surface mount directly to the wall or 1-gang box Overall Dimensions 7-1⁄16″ H x 9-⅛” W x 4-¼”… Read More
KMB-45 Technical Specifications
custom-icon
Line Drawing   Specifications Features 45˚ Mullion Mounting Bracket for C-D, GT-D, IF-DA, IX-BA, IX-DA, JO-DA, JP-DA, KB-DAR, KB-DAR-M, or LE-D Can mount to either right or left of the door Mounting Surface mount directly to the wall or mullion Dimensions 5-1/2” H x 5-1/2” W… Read More
MKW-P Technical Specifications
custom-icon
Line Drawing   Specifications Features Adapts the JF-DV, JK-DV, JO-DV, and JP-DV surface mount door stations to a standard 1-gang box or ring Material Fire-retardant plastic Mounting Single-gang box Dimensions 7” H x 4” W x  3/8” D… Read More
AC-10S Technical Specifications (Discontinued)
custom-icon
Line Drawing   Specifications Power Source 12-24V AC or DC Current Consumption AC: 100mA (max.) DC: 70mA (max.) Number of Relays 2 Relay Contact Capacity 24V DC, 3A (resistive load) 1A (inductive load) 24V AC, 3A (resistive load) 1A (inductive load) Mounting Surface wall mount Protection Rating IP54 Operating… Read More
JF-2HD Technical Specifications
custom-icon
JF-2HD Line Drawing Specifications Power Source 18V DC (Supplied by PS-1820UL) Current Consumption Maximum 220mA Communication Hands-free or Push-to-talk Screen 3.5″ TFT color LCD Picture Memory 50 Pictures Wiring 4-conductor, PE insulation, Aiphone wire #871804 between stations Wiring Distance JF-2HD to JF-2MED: 330′ Mounting Surface wall mount Electrical Box… Read More
JF-2SD Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC supplied by JF Master Station Current Consumption Maximum 120mA and in standby 40mA Communication Hands-free or Push-to-talk Wiring 2-conductor, PE insulation, Aiphone wire #871802 between stations Wiring Distance Door to farthest JF-2SD: 330′ Mounting Surface wall mount Electrical Box Single-gang box Operating… Read More
JF-2HD Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC (Supplied by PS-1820UL) Current Consumption Maximum 220mA Communication Hands-free or Push-to-talk Screen 3.5″ TFT color LCD Wiring 4-conductor, PE insulation, Aiphone wire #871804 between stations Wiring Distance Door to farthest JF-2HD: 330′ Mounting Surface wall mount Electrical Box Single-gang box Operating Temperature… Read More
JF-2MED Technical Specifications
custom-icon
JF-2MED Technical Specifications Line Drawing Specifications Power Source 18V DC (Supplied by PS-1820UL) Current Consumption Maximum 400mA Communication Hands-free or Push-to-talk Screen 3.5″ TFT color LCD Picture Memory 50 pictures Wiring 4-conductor, PE insulation, Aiphone wire #871804 between stations 4-conductor, PE insulation, Aiphone wire #871802 between master station and… Read More
JF-DVF-HID Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC supplied by JF Series Master Station Communication Hands-free Camera 1/4″ CCD Camera Angle 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Card Reader HID® ProxPoint® Plus reader (6005B) Wiring 2-conductor, PE insulation, Aiphone wire #871802 Wiring… Read More
JF-DVF Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC supplied by JF Series Master Station Communication Hands-free Camera 1/4″ CCD Camera Angle 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Wiring 2-conductor, PE insulation, Aiphone wire #871802 Wiring Distance Door Station to Master Station: 165′… Read More
JF-DV Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC supplied by JF Series Master Station Communication Hands-free Camera 1/4″ CCD Camera Angle 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Wiring 2-conductor, PE insulation, Aiphone wire #871802 Wiring Distance Door Station to Master Station: 165′… Read More
JF-DA Technical Specifications
custom-icon
Line Drawing Specifications Power Source 18V DC supplied by JF Series Master Station Communication Hands-free Camera 1/4″ CCD Camera Angle 2′ 1″ vertical x 3′ 1″ horizontal at 20″ Minimum Illumination 5 lux Wiring 2-conductor, PE insulation, Aiphone wire #871802 Wiring Distance 165′ (22 AWG) 330′ (18 AWG)… Read More
JF-D Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied from JF Master Station Type of Communication Open voice handsfree communication Wire 2-conductor, PE insulation, Aiphone wire #871802 Wiring Distance Door Station to Master Station: 165′ (22 AWG) 330′ (18 AWG) Mounting Surface wall mount Electrical Box Single-gang box Operating Temperature 14°~140°F (-10°~60°C)… Read More
JF-2MED Technical Specifications
custom-icon
JF-2MED Line Drawing   Specifications Power Source 18V DC (Supplied by PS-1820UL) Current Consumption Maximum 400mA Communication Hands-free or Push-to-talk Screen 3.5″ TFT color LCD Picture Memory 50 Pictures Door Release Contact 24V AC/DC, 0.5A (N/O Dry Contact Closure) Wiring 2-conductor, PE insulation, Aiphone wire #871802 from doors &… Read More
Modifications
Wiring: JF Series with the RY-3DL
custom-icon
Summary The JF-2MED can release 2 door strikes when using the RY-3DL. Wire the system as shown below to use the single door release button to activate the strike associated with the door station that is in communication with the master station.   Wiring Diagram… Read More
Wiring Diagrams
Wiring: JF Series with the RY-3DL
custom-icon
Summary The JF-2MED can release 2 door strikes when using the RY-3DL. Wire the system as shown below to use the single door release button to activate the strike associated with the door station that is in communication with the master station.   Wiring Diagram… Read More
Wiring: JF Series Complete System
custom-icon
Wiring Diagram PS-1 represents the PS-1820UL power supply. PT represents the power supply required by release mechanism, contact manufacturer for more information Wiring Distances JF Door Station to JF-2MED: 330′ JF-2MED to JF-2HD/SD: 330′ (farthest sub master station)   Notes Wire specification:… Read More
External Signaling JO, JK, JF, JP, KB, IE
custom-icon
JF Series – Wiring Door Stations and Power Supply
custom-icon
https://www.youtube.com/watch?v=iwaEzdUKZ2g
Common Issues
No Audio at Door Station but Video Works at Master Station
custom-icon
Summary During a call the user receives no audio at the door station, however, video works at the master station receiving the call.   Cause A mismatch of door stations, incompatible door station with the master station.   Solution Verify the model number of the master station. If the master… Read More

Transform Your Security Today

Connect with our local experts for product questions, demos, and assistance in designing your ideal security solution.

Contact Us

Recent Articles

Stay current with our latest technical resources. We update them regularly to support your evolving security needs.

GT Series, Wiring Diagrams
General GT Expanded Video Loop Wiring Diagram
GT Series, Wiring Diagrams
General GT Standard Video Loop Wiring Diagram
Firmware & Software, IXG Series
IXG-2C7 Enhanced Firmware Ver. 4.80
IX Series, IX Series Application Notes
MB-RF1 Instructions