TECHNICAL KNOWLEDGE BASE
Wiring Diagrams
Wiring Diagrams
Wiring Diagrams
External Signaling with the AX Master Station
Summary Steps on connecting an external signaling device such as a chime or bell to an AX master station. Solution Follow the diagram below using the 6-pin connector included with the AX master station. Step 1 Connect Brown (V+) and Red (V-) to standard coax monitor / DVR input. Read More
AX Series Open Collector Output
Summary The AX-084C and AX-248C have open collector outputs to trigger a recording device when there is a video signal present on the V1 and V2 video outputs. The open collector outputs labeled VCH1 and VCH2 can be used in conjunction with the RY-24L relay. The diagram below shows this… Read More
AX Series with Viking K-1900-5 and RC-2A for CO Line Transfer and Door Release
Summary The Viking K-1900-5 is used for the CO Line Transfer mode, transferring a door station call to a programmed telephone number. With communication established on the phone line, the Viking RC-2A allows the telephone to trigger a single door release contact. Wiring Diagram Max. distance from each… Read More
Transform Your Security Today
Connect with our local experts for product questions, demos, and assistance in designing your ideal security solution.
Contact Us
Recent Articles
Stay current with our latest technical resources. We update them regularly to support your evolving security needs.