NH-1SA-A Technical Specifications
custom-icon
Line Drawing Specifications Power Source Provided by NHX-80 Communication Hands-free Communication Output 100mW @ 20 ohms Calling Capacity Up to 80 stations Wiring 3 twisted pair shielded low capacitance cable (12 pF/Ft) from NHX-80X Aiphone #862208 With NHR-3A-4 Zone Indicator Light: 3 twisted pair + 1 common wire… Read More
NHX-80X Technical Specifications
custom-icon
Line Drawing Specifications Power Source 24V DC supplied by two PS-2420UL power supplies Current Consumption Maximum 4A Station Capacity 50 Stations. For an additional 30 stations add NHR-30K. Wire Type All wire is twisted, shielded, low capacitance (12 pF/Ft). 5 twisted pair to NHX-50M Master Station – Aiphone… Read More
NHR-30K Technical Specifications
custom-icon
Line Drawing Specifications Mounting Mounts to back of NHX-80X Station Capacity Allows for an additional 30 stations to be integrated with the NHX-50M with the use of NHX-30G Weight Approx. 0.37 lbs (170g)… Read More
NHX-50M Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Control Unit (NHX-80M) Power Consumption 80mA Standby, 500mA Maximum Communication Handset or Push-to-talk Capacity 50 Stations Call Priority Cord-out trouble call Urgent bathroom call and NHR-3TS common area bathroom/staff call Routine call (sub station call-ins on standby connected according to urgency… Read More
NHX-30G Technical Specifications
custom-icon
Line Drawing Specifications Features Plugs into NHX-50M with supplied connectors Expands NHX-50M to an 80-call master station Mounting Desktop use Operating Temperature 32° ~ 104°F (0° ~ 40°C) Dimensions 2-5/16” H x 3-9/16” W x 8-1/4” D… Read More
NH-2SA/A Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Control Unit (NHX-80M) Communication Open Voice Hands-free communication Wiring Sub Station or Duty Station to Central Control Unit: 4 twisted pair, low cap, PE, overall shield — use Aiphone #862208 Wiring Distance Sub Station to Central Control Unit: 165′(22 AWG)… Read More
NH-1SA/A Technical Specifications
custom-icon
Line Drawing Specifications Power Source Supplied by Central Control Unit (NHX-80M) Communication Open Voice Hands-free communication Wiring Sub Station or Duty Station to Central Control Unit: 4 twisted pair, low cap, PE, overall shield — use Aiphone #862208 Wiring Distance Sub Station to Central Control Unit: 165′(22 AWG)… Read More
NHR-SP Technical Specifications
custom-icon
Line Drawing Specifications Features Alerts staff when a master station receives a call (urgent calls override routine calls) Acknowledges any station call with tone and blinking LED (use NHX-50M to identify caller or to answer call) Power Source Supplied by Central Control Unit (NHX-80M) Communication Open Voice Hands-free communication… Read More
NHR-3TS Technical Specifications
custom-icon
Line Drawing Specifications Features Two red lamps, registered as one sub station, distinguished at calling location. NHR-3RS displays a red light flashing to indicate bathroom call or Staff call, which has been placed from Bathroom/Urgent call station (NHR-7A) Power Source Supplied by Central Control Unit (NHX-80M) Wiring Sub Station… Read More
NHR-8C Technical Specifications
custom-icon
Line Drawing Specifications Features Button activates routine call at the master station Cord-out activates urgent call at the master station Capacity One for NH-1SA/A, and two for NH-2SA/A Connector 1/4″ ‘L’ phone jack Mounting Plugs into bedside sub station Weight Approx. 0.24lbs (110g) Dimensions Cord length 7′ Handheld button… Read More
NHR-7A Technical Specifications
custom-icon
Line Drawing   Specifications Features Latching call switch Waterproof for bathroom areas Durable and strong nylon pull cord with pendant Can be used without cord as urgent call station (with NHR-3TS) LED “call placed” indicator Power Source From call station Wiring 3 conductors to associated call station Use Aiphone… Read More
NHR-4A Technical Specifications
custom-icon
Line Drawing   Specifications Features White lamp for a bedside call Red lamp for a bathroom call Power Source From call station Power Consumption Max. 2.4W per bulb Lamp Rating 24V, 100mA Wiring 3 conductors to associated call station Use Aiphone #862208 for color-code matching, or Aiphone… Read More

Transform Your Security Today

Connect with our local experts for product questions, demos, and assistance in designing your ideal security solution.

Contact Us

Recent Articles

Stay current with our latest technical resources. We update them regularly to support your evolving security needs.

AC Series, AC Series Application Notes
AC Series – AC Nio™ Life Safety Mode and Expired Licenses
IX Series, IX Series Application Notes
IX-DVF-10KP Instructions
IX Series, Specifications
IX-DVF-10KP Specifications
IX Series, Qumulex
IX|IXG Series Qumulex® QxControl™ Integration