TECHNICAL KNOWLEDGE BASE Application Notes

Application Notes

banner
Application Notes
GT-MK Factory Reset
custom-icon
Summary Used when GT-MK needs to be reset to factory default, or if it is stuck in a certain status, such as reception mode, connecting, and others.   Solution Turn on all dip switches (1-4) on SW1. Turn on the power while pressing the Door Release and Light buttons. Release these buttons… Read More
GT-DM Factory Reset
custom-icon
Summary Steps on factory resetting a GT-DM or GT-DMA Entrance Station.   Solution Turn on all switches (1-4) of SW1 and switches 2, 3, and 4 of SW2. Turn on the power while pressing down the up and down arrow buttons. Release the up arrow button after a beep is… Read More
Programming Resident Info New GT-MKB-N
custom-icon
Summary Steps on programming an apartment number and name in a GT-MKB-N.   Solution Press the Settings button. Use the down arrow key to select Advanced Settings and press the Zoom button to enter the settings. Use the down arrow key to select Program Mode and press the Zoom button… Read More
Adding or Editing Resident Information on a GT-DMB-N
custom-icon
Summary How to enter or edit existing information on a GT-DMB-N or modular entrance station.   Solution From the keypad enter # * 1111. The display will show “Re-enter code”, enter * 1111. You should now see the selection Language. Use the arrow keys and scroll to System Settings press green Bell button. Read More
Add NFC Cards and Devices to GT-DMB-N
custom-icon
Summary Steps on entering NFC cards and NFC-enabled devices into the GT-DMB-N.   You will need the authorization code for the GT-DMB-N to continue with the steps below. By default the authorization code is set to 1111   Solution Enter program mode by… Read More
How to Program NFC Cards to Release the Door on a Multi-button GT Entrance Station
custom-icon
Summary Setting up NFC access cards for a standard multi-button entrance station (non-digital displays) using the free Aiphone GT Setup Tool for Android® phones with NFC capability.   Solution Before beginning this procedure, the GT Series will need to be completely… Read More
Activating a Man Trap With the GT Series
custom-icon
See attached PDF.
GT Series Remote Programming
custom-icon
See attached PDF.
Using Two GT-1C7 Stations per Tenant Location
custom-icon
See attached PDF.
Deleting Resident Information from GT Panels
custom-icon
This guide explains how to delete resident information from current and legacy GT panels and guard stations.
Error 101 in GT Setup Tool
custom-icon
This guide covers the cause of and resolution to Error 101 when uploading using the GT Setup Tool.
GT, GH, & GF Series Tenant Station Compatibility
custom-icon
This chart shows which tenant stations from the GT, GH, and GF Series are compatible with other series, and what currently available station can take its place, if one is available.     ✓… Read More

Transform Your Security Today

Connect with our local experts for product questions, demos, and assistance in designing your ideal security solution.

Contact Us

Recent Articles

Stay current with our latest technical resources. We update them regularly to support your evolving security needs.

IX Series, Qumulex
IX|IXG Series Qumulex® QxControl™ Integration
Alcatel-Lucent, IX Series, IXG Series, IXG Series Application Notes
Alcatel Integration
IXG Series, IXG Series Application Notes
Adding and Removing IXG App Users with the IXG App Portal
IXG Series, Programming
Log Tool for IXG-DM7-HID(A) Instructions