VC-M System Troubleshooting
VC-M Trouble Shooting
1. No Call Tone, but communication to and from the handset is fine.
Perform jumper test between terminals 1 and B. If no call tone, the unit is defective. If call tone sounds, check wiring between B on the VC-K and the button terminal on the VC-M panel. Make sure that the black common bus wire for all the call switches is connected to the B terminal of the VC-M panel. If still no call tone, switch B wire to different call button switch. If call tone is heard, then the button is bad. Otherwise recheck wiring.
Refer to VC-M Instructions.
2. No communication from VC-K to VC-M.
Check wiring between 1 of VC-M and 1 of VC-K.
3. No communication from VC-M to VC-K.
Check wiring between 2 of VC-M and 2 of VC-K.
4. Communication is fine, but no door release.
Check the wiring between 4 of the VC-K and 4 of the VC-M. Check to make sure the RY-PA relay is properly attached (black leads to L+ and L-).
Refer to VC-M Instructions.
Buy Aiphone
Are you interested in purchasing Aiphone in your local area? Click here to find a location near you!
Aiphone Training
Visit aiphonetraining.com to find continuing education programs on-line. You can choose between sales and technical education.
Quik Links
QuikSpec Plus!
Aiphone is proud to offer an enhanced version of our classic QuikSpec program. QuikSpec Plus provides you the opportunity to save your specs to your profile and even saves them in Excel, Word, and PDF formats. Once exported to the format of your choice, you can add pricing to your specs and include them in your A&E specs.
Registration is FREE. Sign up today!
Chat with Us!
Use our new QuikChat feature to chat real time with a member of our technical support or customer service departments (Requires Pop-ups). This service is only available in the United States and Canada.