1. C-123L system has a buzz or hum.
Wire was run too close to AC voltage or fluorescent lights. Shielded wire is recommended. If shielded wire was run, connect one end of the shield to an earth ground.
Refer to C-123L Instructions.
2. Newly installed C-123LW, feedback when either master tries to communicate with the door.
Is there only one power supply for both masters? C-123LW requires two SKK-620’s, one per master (or 4 "C" batteries in each master.)
Refer to C-123LW Instructions.
3. Newly installed C-123LW, when one master tries to communicate with the door a chime tone is heard at the other master.
Dual Adapter Kit (DAK-2S) is not installed, or installed backwards.
Refer to C-123LW Instructions.
4. Newly installed unit is totally dead.
Make sure unit has 6V DC (12V DC will severely damage the unit).
Make sure power connections are on + and - terminals. (Check to make sure the wires on the - and 1 terminals are not reversed.)Refer to C-123L Instructions.
Buy Aiphone
Are you interested in purchasing Aiphone in your local area? Click here to find a location near you!
Aiphone Training
Visit aiphonetraining.com to find continuing education programs on-line. You can choose between sales and technical education.
Quik Links
QuikSpec Plus!
Aiphone is proud to offer an enhanced version of our classic QuikSpec program. QuikSpec Plus provides you the opportunity to save your specs to your profile and even saves them in Excel, Word, and PDF formats. Once exported to the format of your choice, you can add pricing to your specs and include them in your A&E specs.
Registration is FREE. Sign up today!
Chat with Us!
Use our new QuikChat feature to chat real time with a member of our technical support or customer service departments (Requires Pop-ups). This service is only available in the United States and Canada.