NDR: Lamp Memory Security Intercom System

System Components
- PC-359B
- NDR-20
- NDR-20A
- NDR-40A
- NA-A
- NA-AN
- NA-NE
- NB-L
- NA-T/A
- NE-DA
- NE-JA
- NE-SS
- NE-SS-1G
- NE-SSR
- NE-NVP/C
- NE-NVP-2DC
- NEW-5
- NB-U
- NAR-2A
- NAR-6A
- NBY-1A
- NBR-8A
- NBY-4A
- N-EA
- NBZ-M
- NBX-2
- RY-PA-10
- PS-2420UL
- BA-1
- Paging Amplifiers
Features
- Lamp memory call-in from subs - the LED light will stay lit until call is answered
- Extra contact capability for every station
- Selective door release using one RY-PA per door
- All components of the NEM system are compatible
NDR CAD drawings available - download here
Specifications
| Power Source | 24V DC - Use PS-2410A (1~20 stations) 24V DC - Use PS-2420UL (21~40 stations) |
| Calling | Master to sub: By voice only after pre-tone Sub to master: Call tone and LED, remaining lit until call is answered |
| Door Release | RY-PA contact rating: 24V DC, 1A |
| Communication | Push-to-talk, release to listen or VOX with handset Hands-free at sub station |
| Communication Output | 500mW max. |
| Wiring | Doors to masters: 2-cond., overall shield NEW-5 to master: 10-cond., overall shield |
| Distance | Doors to masters: 420’(22AWG) 1,000’(18AWG) |
| Wire Type | Doors to masters: Aiphone #822202 or Aiphone #821802 |
Product Literature
- BA-1 Instructions (64.59 KB)
- N-EA Instructions (85.62 KB)
- NEM Subs Spec Sheet (27.37 KB)
- NA-T/A Instructions (140.68 KB)
- NB-L Instructions (93.30 KB)
- NB-U Instructions (281.43 KB)
- NBX-2 Instructions (14.98 KB)
- NBX-2 Spec Sheet (44.67 KB)
- NDR-10/20/30/40 Instructions (83.58 KB)
- NDR Spec Sheet (50.36 KB)
- NE-DA Instructions (68.70 KB)
- NE-DA, NE-JA Spec Sheet (134.20 KB)
- NE-JA Instructions (347.50 KB)
- NE-NVP-2DC Instructions (24.03 KB)
- NE-NVP-2DC Spec Sheet (92.59 KB)
- NE-NVP/C Instructions (102.52 KB)
- NE-SS/SSR Instructions (51.88 KB)
- NE-SS/SSR Spec Sheet (98.44 KB)
- NE-SS-1G Instructions (95.92 KB)
- NE-SSV Instructions (236.41 KB)
- NEW-5 Instructions (285.76 KB)
- Paging Amplifiers Instructions (298.38 KB)
- PC-359B Instructions (84.00 KB)
- PS-2420UL Instructions (103.56 KB)
- RY-PA Spec Sheet (43.52 KB)
- RY-PA-10 Instructions (73.63 KB)
- RY-PA-10 Spec Sheet (87.53 KB)
Modification Manual(s) Available
| Modification | Difficulty |
|---|---|
| NDR Call Extension options (90.54 KB) | Level 2 - Easy/Moderate |
| NDR External All Call Amp (31.69 KB) | Level 2 - Easy/Moderate |
| NDR Extra closure at sub (53.24 KB) | Level 2 - Easy/Moderate |
| NDR Over 40 subs and BGM (58.70 KB) | Level 2 - Easy/Moderate |
| NDR Timer for tone generator (51.08 KB) | Level 2 - Easy/Moderate |
| NDR Exclude subs from all call (142.90 KB) | Level 3 - Moderate |
| External signaling at NA-T/A (64.71 KB) | Level 4 - Moderate/Hard |
| NDR Call initiation from sub when NA-T/A is also used. (24.69 KB) | Level 4 - Moderate/Hard |
| NDR Dual master with selective call remote stations (70.35 KB) | Level 4 - Moderate/Hard |
| NDR with LE sub (8.65 KB) | Level 4 - Moderate/Hard |
| PC-359B, PC-454 Connection (135.20 KB) | Level 4 - Moderate/Hard |
| NDR LED monitoring indicator on sub station (148.41 KB) | Level 5 - Hard |
All modifications are ranked into these five levels of difficulty:
- Level 1 - Easy
- Wire Connection Only
- Level 2 - Easy/Moderate
- Component Connection to External points
- Level 3 - Moderate
- Removal and replacement of internal Components
- Level 4 - Moderate/Hard
- Internal connection or component addition
- Level 5 - Hard
- Circuit Creation and Internal Addition
Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.
Buy Aiphone
Are you interested in purchasing Aiphone in your local area? Click here to find a location near you!
Customer Portal
The Customer Service web portal is for direct account customers* to access important product and account information 24/7! You will be able to look up:
Pricing, Product Availability, Order Status (open or shipped), Package Tracking, Invoice Inquiry, and Payment Inquiry.
* If you are not already signed up, contact cs@aiphone.com and we will direct you to the Account Administrator for your company. If you are the person that will administer access to this site for your company, click here.
Aiphone Training
Visit aiphonetraining.com to find continuing education programs on-line. You can choose between sales and technical education.
See Aiphone!
To view all of our upcoming shows, visit our Trade Show page.
Quik Links
QuikSpec Plus!
Aiphone is proud to offer an enhanced version of our classic QuikSpec program. QuikSpec Plus provides you the opportunity to save your specs to your profile and even saves them in Excel, Word, and PDF formats. Once exported to the format of your choice, you can add pricing to your specs and include them in your A&E specs.
Registration is FREE. Sign up today!
Chat with Us!
Use our new QuikChat feature to chat real time with a member of our technical support or customer service departments (Requires Pop-ups). This service is only available in the United States and Canada.
LIT REQUEST
IMAGE REQUEST
Image Request
Contact Aiphone for print quality images! Click here to request product photos.