AP-M: High-Power Intercom System

AP-M: High-Power Intercom System by Aiphone

System Components

Features

  • High-powered 10W output for large or high noise areas.
  • One or two masters can be included.
  • Hands free reply from remote area.
  • AP-1M, AP-5M, or AP-10M master stations available, desk or wall mount.
  • Use 8 ohm horn speaker for maximum output, or wall or ceiling speaker sub stations.
  • Subs call master with LED and electronic tone.
  • Built-in power supply.  
AP-M CAD drawings available - download here

Specifications

Power Source
110~125V AC, 50/60Hz.
Communication
Sub calls in with tone and LED, 15 sec., depress selector and use TALK/LISTEN switch, All Call selectively to max. 5 subs, max. 10W transmit (adjustable), 300mW receive (adjustable)
Communication Output
10W
Wiring
Doors/Subs/Horns to master: 2-cond., overall shield
Distance
Doors/Subs/Horns to master: 490’(22AWG) 1,200’(18AWG)
Wire Type
Aiphone #822202 or Aiphone #821802

Product Literature

Modification Manual(s) Available

Free PDF downloads for in field technicians.
ModificationDifficulty
AP-M Zone Paging (17.94 KB)Level 1 - Easy
AP-M External Signaling (222.77 KB)Level 2 - Easy/Moderate
AP-M Increase receive volume at master station (199.29 KB)Level 3 - Moderate
AP-M Lamp memory on a single-master (15.55 KB)Level 3 - Moderate
AP-M Add Background music (238.58 KB)Level 4 - Moderate/Hard
AP-M Call tone activation while in monitoring mode (200.48 KB)Level 4 - Moderate/Hard
AP-M Extending the LED timing circuit for a longer period of time (190.22 KB)Level 4 - Moderate/Hard
AP-M Increase communication volume between master stations (193.18 KB)Level 4 - Moderate/Hard
AP-M Increase the incoming call tone volume from a sub (188.02 KB)Level 4 - Moderate/Hard
AP-M Long distance communication (2500' max.) (206.69 KB)Level 4 - Moderate/Hard
AP-M Using an LE series sub station (96.29 KB)Level 4 - Moderate/Hard
AP-M Using UL Listed power supplies (110.99 KB)Level 4 - Moderate/Hard
AP-M LED monitoring indicator on a sub station (237.97 KB)Level 5 - Hard
AP-M Tape recorder output (23.14 KB)Level 5 - Hard

All modifications are ranked into these five levels of difficulty:

Level 1 - Easy
Wire Connection Only
Level 2 - Easy/Moderate
Component Connection to External points
Level 3 - Moderate
Removal and replacement of internal Components
Level 4 - Moderate/Hard
Internal connection or component addition
Level 5 - Hard
Circuit Creation and Internal Addition

Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.

Download Adobe Acrobat Reader

Buy Aiphone

Are you interested in purchasing Aiphone in your local area? Click here to find a location near you!

Aiphone Training

Visit aiphonetraining.com to find continuing education programs on-line. You can choose between sales and technical education.

See Aiphone!

To view all of our upcoming shows, visit our Trade Show page.

Quik Links

QuikSpec Plus!

Aiphone is proud to offer an enhanced version of our classic QuikSpec program.  QuikSpec Plus provides you the opportunity to save your specs to your profile and even saves them in Excel, Word, and PDF formats.  You can now add pricing to your specs and even have the ability to include them in your A&E specs.

Registration is FREE. Sign up today!

Chat with Us!

Use our new QuikChat feature to chat real time with a member of our technical support or customer service departments (Requires Pop-ups). This service is only available in the United States and Canada.

 

Facebook

Follow Us On Facebook!

IMAGE REQUEST

Image Request

Contact Aiphone for print quality images!  Click here to request product photos.