VC-M: Multi-Tenant Audio Entry System
The VC-M Series is a Multi-Tenant Audio Entry System. The system supports 1 entry panel and is scalable to as many tenants as required.
Features »
  • Entrance panels available in a variety of sizes: 2, 4, 6, and 10 call buttons
  • Add-on panels with 8 or 16 call buttons
  • Directory panel is backlit
  • Up to two handsets per apartment
  • Optional external signaling (RY-PA required)
Specifications »
Power Source
12V DC, 80mA (intercom), 100mA (lamp) - Use PS-1225UL
Communication
Electronic buzzer rings VC-K station(s), frequency is approx. 600Hz, pick up (either) handset too reply
Wiring
Door to master: 5-cond., non-shielded Between masters (6 looped): 10-cond., non-shielded Between masters (12 looped): 16-cond., non-shielded
Distance
Door to master: 500’(22AWG)
Wire Type
Door to room station or tenant station: Aiphone #812205
Between room station or tenant station (6 looped): #812210 Between room station or tenant station (12 looped): #812216
VC-M: Multi-Tenant Audio Entry System
The VC-M Series is a Multi-Tenant Audio Entry System. The system supports 1 entry panel and is scalable to as many tenants as required.
Component List
VC-0M
0-call entrance station (speaker only)
VC-10M
10-call entrance panel.
VC-2M
2 call entrance panel.
VC-4M
4 call entrance panel.
VC-6M
6 call entrance panel.
VC-8M
8 call entrance panel.
VCH-16
The VCH-16 is a 16 button add on panel for the VC-M system.
VCH-8
The VCH-8 is an 8 button add on panel for the VC-M system.
VC-K
The VC-K is a tenant handset room station for the VC-M system.
VC-BBX
The VC-BBX is a surface mount box for the VC-nM and VCH entrance panels.
EL-12S
Electric Door Strike - The EL-12S door strike is designed for wood framed wooden doors. The unit operates on 12~16 V AC.
PS-1225UL
Power Supply - The PS-1225UL is a 12V DC, 2.5 Amp Power Supply. It is UL listed and can be used in both 110V AC and 240V AC environments by changing the AC power cord (110V cord is included with the unit).
Features
Entrance panels available in a variety of sizes: 2, 4, 6, and 10 call buttons
Add-on panels with 8 or 16 call buttons
Directory panel is backlit
Up to two handsets per apartment
Optional external signaling (RY-PA required)
Specifications
Power Source
12V DC, 80mA (intercom), 100mA (lamp) - Use PS-1225UL
Communication
Electronic buzzer rings VC-K station(s), frequency is approx. 600Hz, pick up (either) handset too reply
Wiring
Door to master: 5-cond., non-shielded Between masters (6 looped): 10-cond., non-shielded Between masters (12 looped): 16-cond., non-shielded
Distance
Door to master: 500’(22AWG)
Wire Type
Door to room station or tenant station: Aiphone #812205
Between room station or tenant station (6 looped): #812210 Between room station or tenant station (12 looped): #812216