GM:
Apartment 
Audio/Video 
Entry Security
 

GM: Audio/Video Apartment Entry Security

 

Features (Back to top)

Fully modular entrance panels with designated number of call buttons, from 3 to 32 stations.
Surface or flush mount.
Up to two inside stations, either audio/video, audio-only, or one of each.
Call extension for each inside station (optional).
Access control from inside station to calling entrance.
Use QuikSpec to design this system.
 

 

Product Photos (Back to top)

Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
GMV-4F GMV-8F GM-1MD GM-1D

 

Specifications  (Back to top)

Power Source 24V DC, 0.9A (max. 1.26A).
GM-8A/A: 360mA.
GM-4V: 80mA.
GM-1MD: 410mA.
GM-1D: 50mA.
Power Supply PS-2420UL to GM-8A/A.
Station Capacity 32 Apartments.
Entrance Station One or two.
Apartment Station Two monitor or audio-only stations, or one of each per apartment.
Door Release Contact 12V AC, 0.4A (EL1 or EL2 on GM-8A/A).
GW-V Camera Infrared CCD camera.
GM-1MD Monitor 4" direct view flat CRT
Scanning Line 625 lines
Wiring 4 pair (audio & video) from entrance panel to GM-8A/A,
plus 3 pair (5) + from each button module to GM-8A/A. (Use Aiphone #831808 + #812205.)
3 pair common + 2 pair from GM-8A/A to each GM-4V. (Use Aiphone #831808 + 2 runs of #812205.)
3 pairs from GM-4V to GM-1MD. (Use Aiphone #831808.)
2 pairs from GM-4V to GM-1D. (Use Aiphone #831808.)
Distance Entrance to Apartment: 330' with 18AWG.
Entrance to GM-8A/A: 65' with 18AWG.
GM-8A/A to PS-2420UL: 65' with 18AWG.

 

Click here to QuikSpec this system
Use QuikSpec to design a GM Multi-Unit Entry system  (Back to top)

 

Literature Available (Back to top)

GM Installation Manual
GM Operation Manual
TAR-3 Call Extension Relay Spec Sheet
TAR-3 Call Extension Relay Spec Instructions
PS-2420UL 24V DC, 2 Amp Power Supply Instructions
IER-2 Instructions
 

For additional information contact your Aiphone Representative.
For best results use Internet Explorer or Netscape Navigator 4.0 or above.
For comments about this site: webmaster@aiphone.com