| Specifications
(Back to
top) |
| Power Source |
18V DC, 350mA. Use
PS-1820UL power
supply or 15~16V AC, 50/60Hz. 750mA. |
| Power Consumption |
6W. 3W (standby). |
| Communication |
Pick up TB-SE handset. Rings
TC-M('s)
with tremolo and LED, 40 seconds for door call-in. At TC-M master, pick up and press lit station button. |
| Wiring |
2 wires homerun per TB-SE, non-polarized (Use
Aiphone #822202.) |
| Distance |
Between TC-M Masters: 650' with
22AWG, 1600' with 18AWG.
TC-M to TB-SE: 1300' with 22AWG, 3000' with 18AWG.
TC-M to TB-AD1/AD10: 210' with 22AWG, 500' with 18AWG.
IE/IF Door to TB-AD1/AD10: 500' with 22AWG, 1200' with 18AWG. |
|