Features (Back to top)

Expandable to 120 stations.
Built-in All Call amplifier.
Call-in LED and tone remain until call is answered.
Selective control of remote devices with RY-PA relay for each function.
Door release (selective momentary contact).
Camera call-up (selective maintained contact).
Control of any device or system controlled by relay.
Control of dual devices off of the same channel.
Use QuikSpec to design this system.

Product Photos (Back to top)

 

Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
NDR-10A NDR-10 NE-NVP/B NA-A NA-AN
Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
Click picture to view larger image. Use the "Back" button on your browser to return to this page.
NA-NE NA-T/A NE-SS NE-SSR SBX-2G

 

Specifications (Back to top)
Power Source 24V DC, 45W maximum. 2.5W (standby).   *Use PS-2410A for NDR-10 or NDR-20, or PS-2420UL for NDR-30 or NDR-40.
Communication Pretone and voice at sub when selected.
Sub call-in tone and LED remain, tone muted when in communication.  Press and release Talk/Listen and/or use handset (voice activated).
Output 500mW maximum, adjustable.
All Call: Press ALL CALL switch (6W for 10/20, 12W for 30/40).
Group call up to 10 subs with ind. select switches pressed, then press TALK switch (3W).
Wiring 1 common wire plus 1 individual wire per sub station looped (Aiphone #8222xx wire (xx = # of conductors))., or 2 wires homerun from each sub station (Aiphone #822202 (22AWG) or #821802 (18 AWG)).
Separate 2 conductor to RY-PA and external device
(Aiphone #822202 (22AWG) or #821802 (18 AWG)).
Distance 420' with 22AWG, 1000' with 18AWG.

 

Click here to QuikSpec this system
Use QuikSpec to design an NDR Intercom & Access Control system (Back to top)

 

Literature Available (Back to top)

NDR Access/Camera Control System Spec Sheet
NDR Access/Camera Control System Instructions
NEM Lamp Memory Intercom Instructions
NEW-5 Parallel Call Adaptor for NEM Instructions
NB-U BGM Adaptor Instructions
NEM Sub Station Spec Sheet
NE-NVP/B Vandal Proof Sub Station for NEM Spec Sheet
NE-NVP/B Vandal Proof Sub Station for NEM Instructions
NE-JA Weather Resistant Sub Station Instructions
NA-T/A NEM Handset Sub Station Instructions
NB-L Flush-Mount Round Speaker Instructions
NBX-2 Surface Mount Box for NA-NE Spec Sheet
PC-359B/PC-454 Wiring Instructions
AH-108 8 ohm Horn Speaker
SP-20N Ceiling Speaker for NEM Spec Sheet
T3115BGM and T3130BGM Amplifier Instructions
DMA2060 and DMA2120 Amplifier Instructions
AH-16TN, AH-32TN Paging Horns Spec Sheet
SP-5N Paging Speaker Spec Sheet
PS-2410A 24V DC, 1 Amp Power Supply Spec Sheet
PS-2420UL 24V DC, 2 Amp Power Supply Instructions
TAR-3 Call Extension Relay Spec Sheet
TAR-3 Call Extension Relay Instructions
SA-1 Surge Arrestor Spec Sheet
Wire Chart
RY-PA-10/A 10 Relay Adaptor Spec Sheet
RY-PA-10/A 10 Relay Adaptor Instructions
NE-DA, NE-JA Weather Resistant Sub Station Spec Sheet
NE-DA Weather Resistant Sub Station Instructions
NDR-LD Access/Camera Control System for Long Distance Instructions
NDR-RS Access/Camera Control System for Rescue Assistance Instructions
NE-NVP-RA Spec Sheet
NE-NVP-RA Instructions
NE-NVP-2DC/B Spec Sheet
NE-NVP-2DC/B Instructions
NE-SSV Vandal resistant Sub Station with built-in pinhole camera
NE-SS/NE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Spec Sheet
NE-SS/NE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Instr
SBX-2G Surface Mount Box for NE-SS & NE-SSR Spec Sheet
BA-1 Paging Adaptor Spec Sheet
BA-1 Paging Adaptor Instructions
RMK-01, RMK-02, RMK-03 Spec Sheet

Modifications Available (Back to top)

Aiphone has always recognized that there are features and functions that our products don't have. In response we've created a manual detailing the in-field customization of our units to do some of  the more frequently requested functions. Called the "Modification Manual"  and now in it's fifteenth year, it has been an invaluable source of knowledge for in field technicians. It is available free of charge for the first time here.

All modification are in PDF format and are broken down into 5 levels, based on their difficulty:

Level 1 - Easy - Wire Connection Only
Level 2 - Easy/Moderate - Component Connection to External points
Level 3 - Moderate - Removal and replacement of internal Components
Level 4 - Moderate/Hard - Internal connection or component addition
Level 5 - Hard - Circuit Creation and Internal Addition

Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.

MODIFICATION: DIFFICULTY LEVEL:
Installing PC-359B with speaker and call button 4 - Moderate/Hard
Dual Master System with selective calling remote stations 4 - Moderate/Hard
LED monitoring indicator on a sub station 5 - Hard
Excluding certain sub stations from All Call and BGM 3 - Moderate
Tape recorder output from an NEM master station 5 - Hard
NEM system with over 40 stations and BGM 2 - Easy/Moderate
Lengthen time between rings on master (incoming call) 3 - Moderate
Elimination of pretone, or Lengthening of pretone. 3 - Moderate

Timer/Clock relay to activate tone generator through NEM

2 - Easy/Moderate
Call tone annunciation during monitoring mode 3 - Moderate
Using LE series sub stations with the PC-359B on NEM system 4 - Moderate/Hard
Increase pretone volume to sub station 3 - Moderate
External signaling of an NA-T/A handset sub station 4 - Moderate/Hard
Call initiation from NA sub when an NA-T/A is also used 4 - Moderate/Hard
Call extension on the NEM system 2 - Easy/Moderate
Extra closure from sub station when call is placed 2 - Easy/Moderate
External amplifier for louder All Call volume 2 - Easy/Moderate

For additional information contact your Aiphone Representative.
For best results use Internet Explorer or Netscape Navigator 4.0 or above.
For comments about this site: webmaster@aiphone.com
Copyright 2002 by Aiphone Corporation - All rights reserved.

Got  questions?

Use "QuikFAQ" to get instant answers!

Click the logo below to get started.