LEF
Series:
Selective Call
Open Voice
Intercom
|
|
|
|
|
Features
(Back to top)
|
|
|
|
Product Photos
(Back to top)
|
| Specifications
(Back to
top) |
| Power Source |
12V DC, 300mA per station. *Use
PS-1225UL
power supply. |
| Communication |
Subs call in with call tone and LED, 20 sec.
Depress station button with lit LED. Press to talk, hands free reply.
No LED annunciation between masters.
Hands free reply from responding master.
*800mW receive at 20ohms. 500mW transmit at 20ohms. |
| Door Release Button Contact |
30V DC, 0.1A (resistance load). |
| Selector Switch Contact |
12V DC, 300mA. |
| Wiring |
Use shielded multi-conductor wire, not twisted
pairs.
2 conductors per sub, homerun (single master system), or 3 conductors per sub
(multi-master system). (Use Aiphone #822202 or #822203.)
LEF-3 requires 9 conductors between masters. (Use Aiphone #822210.)
LEF-5 requires 12 conductors between masters (plus up to 5 for video/door release
controls). (Use Aiphone #822212 or greater.)
LEF-10 requires 17 conductors between masters (plus up to 10 for video/door release
controls). (Use Aiphone #822220.)
LEF-10S requires 20 conductors between masters (plus up to 20 for video/door release
controls). (Use Aiphone #822220.) |
| Distance |
650' with 22AWG, 1600' with 18AWG. |
|
|

Use QuikSpec to design an LEF
Open Voice system.
(Back to top)
|
|
Literature Available (Back
to top)
 |
PS-1225UL
12V DC, 2.5 A Power Supply Instructions |
 |
EL-9S Door Strike Spec Sheet |
 |
RY-PA Spec Sheet |
 |
RY-AC Spec Sheet |
 |
RY-AC Instructions |
 |
SP-20N Ceiling Speaker for LEF Spec Sheet |
 |
SA-1 Surge Arrestor Spec Sheet |
 |
Wire
Chart |
 |
LEF-3L 3-Call Master Station with Selective Door Release Instructions |
 |
LEF-3L 3-Call Master Station with Selective Door Release Spec
Sheet |
 |
BA-1
Paging Adaptor Spec Sheet |
 |
BA-1 Paging Adaptor Instructions |
 |
LE-B2,
4, 6, 10 Selective Call Entry Station Spec Sheet |
 |
LE-B2, 4, 6, 10 Selective Call Entry Station Instructions |
 |
LE-B2, 4, 6, 10 Selective Call Entry Station Mounting |
 |
Brass Door Station Covers Spec Sheet |
 |
LS-NVP/B Vandal Proof Sub Station Spec Sheet |
 |
LS-NVP/B Vandal Proof Sub Station Instructions |
 |
LE-SSV Vandal resistant Sub Station with built-in pinhole camera |
 |
LE-SS/LE-SSR
2-Gang Stainless Steel, Vandal and Weather Resistant Subs Spec Sheet |
 |
LE-SS/LE-SSR
2-Gang Stainless Steel, Vandal and Weather Resistant Subs Instr |
 |
SBX-2G
Surface Mount Box for LE-SS & LE-SSR Spec Sheet |
 |
RY-PA-10/A 10 Relay
Adaptor Spec Sheet |
 |
RY-PA-10/A 10 Relay Adaptor Instructions |
|
|
Modifications Available (Back
to top)
|
|
Aiphone has always recognized that there are
features and functions that our products don't have. In response we've created a
manual detailing the in-field customization of our units to do some of the
more frequently requested functions. Called the "Modification Manual"
and now in it's fifteenth year, it has been an invaluable source of knowledge
for in field technicians. It is available free of charge for the first time
here.
All modification are in PDF format and are broken
down into 5 levels, based on their difficulty:
Level 1 - Easy - Wire Connection Only
Level 2 - Easy/Moderate - Component Connection to External points
Level 3 - Moderate - Removal and replacement of internal Components
Level 4 - Moderate/Hard - Internal connection or component addition
Level 5 - Hard - Circuit Creation and Internal Addition
Please note that modifying a unit will not void
it's warranty unless while doing the modification you damage the unit. Aiphone
is not liable for any damaged caused during modification. Modifications should
only be performed by a person with the skills and knowledge necessary to
successfully complete the modification.
|
|
|
|
|
For additional information contact your Aiphone Representative.
For best results use Internet Explorer or
Netscape Navigator 4.0 or above.
For comments about this site: webmaster@aiphone.com
Copyright 2002 by Aiphone Corporation - All rights reserved.
|