LEF Series: 
Selective Call 
Open Voice 
Intercom 

LEF Selective Call Intercom, Open Voice

 

Features (Back to top)

Flexible system design, intermixing any number of masters and subs to the system's capacity
Selective calling from any master, with hands free reply from sub or responding master.
Room monitoring from a master station.
PanTilt video door answering can be added.
Selective door release (LEF-5, 10 and 10S), with RY-PA relays.
All Call (LEF-10S), door chime and background music input with BG-10C and PS-1225UL.
Use QuikSpec to design this system.
Troubleshooting FAQ's for the LEF System
Literature Available

 

Product Photos (Back to top)

Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
LEF-3 LEF-5 LEF-10 LEF-10S LE Series Sub Stations
Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
LE-D LE-DA LS-NVP/B LE-SS LE-SSR

 

Specifications (Back to top)
Power Source 12V DC, 300mA per station.  *Use PS-1225UL power supply.
Communication Subs call in with call tone and LED, 20 sec.
Depress station button with lit LED.  Press to talk, hands free reply.
No LED annunciation between masters.
Hands free reply from responding master.
*800mW receive at 20ohms.  500mW transmit at 20ohms.
Door Release Button Contact 30V DC, 0.1A (resistance load).
Selector Switch Contact 12V DC, 300mA.
Wiring Use shielded multi-conductor wire, not twisted pairs.
2 conductors per sub, homerun (single master system), or 3 conductors per sub (multi-master system). (Use Aiphone #822202 or #822203.)
LEF-3 requires 9 conductors between masters. (Use Aiphone #822210.)
LEF-5 requires 12 conductors between masters (plus up to 5 for video/door release controls). (Use Aiphone #822212 or greater.)
LEF-10 requires 17 conductors between masters (plus up to 10 for video/door release controls). (Use Aiphone #822220.)
LEF-10S requires 20 conductors between masters (plus up to 20 for video/door release controls). (Use Aiphone #822220.)
Distance 650' with 22AWG, 1600' with 18AWG.

 

Click here to QuikSpec this system
Use QuikSpec to design an LEF Open Voice system. (Back to top)

 

Literature Available (Back to top)

LEF/LEM Product Brochure (1.7M)
LEF-3 3-Call Selective Call Intercom Spec Sheet
LEF-5 5-Call Selective Call Intercom Spec Sheet
LEF-10 10-Call Selective Call Intercom Spec Sheet
LEF-10S 10-Call Selective Call Intercom with All Call Button Spec Sheet
LEF Selective Call Intercom Instructions
LEF Master to audio only sub trouble shooting flowchart
BG-10C Spec Sheet
BG-10C Instructions
LE-A Sub Station Spec Sheet
LE- Door Stations Spec Sheet
LE-D, LE-DA Door Station Instructions
LE-DL Door Station Instructions
AH-108 8 ohm Horn Speaker
T3115BGM and T3130BGM Amplifier Instructions
DMA2060 and DMA2120 Amplifier Instructions
PS-1225UL 12V DC, 2.5 A Power Supply Instructions
EL-9S Door Strike Spec Sheet
RY-PA Spec Sheet
RY-AC Spec Sheet
RY-AC Instructions
SP-20N Ceiling Speaker for LEF Spec Sheet
SA-1 Surge Arrestor Spec Sheet
Wire Chart
LEF-3L 3-Call Master Station with Selective Door Release Instructions
LEF-3L 3-Call Master Station with Selective Door Release Spec Sheet
BA-1 Paging Adaptor Spec Sheet
BA-1 Paging Adaptor Instructions
LE-B2, 4, 6, 10 Selective Call Entry Station Spec Sheet
LE-B2, 4, 6, 10 Selective Call Entry Station Instructions
LE-B2, 4, 6, 10 Selective Call Entry Station Mounting
Brass Door Station Covers Spec Sheet
LS-NVP/B Vandal Proof Sub Station Spec Sheet
LS-NVP/B Vandal Proof Sub Station Instructions
LE-SSV Vandal resistant Sub Station with built-in pinhole camera
LE-SS/LE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Spec Sheet
LE-SS/LE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Instr
SBX-2G Surface Mount Box for LE-SS & LE-SSR Spec Sheet
RY-PA-10/A 10 Relay Adaptor Spec Sheet
RY-PA-10/A 10 Relay Adaptor Instructions

Modifications Available (Back to top)

Aiphone has always recognized that there are features and functions that our products don't have. In response we've created a manual detailing the in-field customization of our units to do some of  the more frequently requested functions. Called the "Modification Manual"  and now in it's fifteenth year, it has been an invaluable source of knowledge for in field technicians. It is available free of charge for the first time here.

All modification are in PDF format and are broken down into 5 levels, based on their difficulty:

Level 1 - Easy - Wire Connection Only
Level 2 - Easy/Moderate - Component Connection to External points
Level 3 - Moderate - Removal and replacement of internal Components
Level 4 - Moderate/Hard - Internal connection or component addition
Level 5 - Hard - Circuit Creation and Internal Addition

Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.

MODIFICATION: DIFFICULTY LEVEL:
External signaling device connected to the LEF system 2 - Easy/moderate
Reducing RF interference 4 - Moderate/hard
Prevention of AC power surge and/or lightning damage 2 - Easy/moderate
Adding selective contact terminals ("K" terminals) to LEF-3/3C 4 - Moderate/hard
Eliminate incoming call tone from sub station at master 3 - Moderate
Installing a volume control on an LE series sub station 5 - Hard
LED monitoring indicator on an LE series sub station 5 - Hard
Tape recorder output 5 - Hard
Selective door release on the LEF system 2 - Easy/Moderate
Various relay contacts using the LEF system 2 - Easy/moderate
Single call sub station to receive All Call and BGM 1 - Easy
Separate transmit and receive volume controls 5 - Hard
Increase LED timing circuit 3 - Moderate
LEF system with and without NP-B call button 1 - Easy
Converting the privacy switch to full time privacy mode 4 - Moderate/hard

For additional information contact your Aiphone Representative.
For best results use Internet Explorer or Netscape Navigator 4.0 or above.
For comments about this site: webmaster@aiphone.com
Copyright 2002 by Aiphone Corporation - All rights reserved.

Got  questions?

Use "QuikFAQ" to get instant answers!

Click the logo below to get started.