ENTRANCE PANEL
KITS:
(Each kit includes the modular components needed to create a complete
entrance station. Assembly at installation is required.)
| MODEL |
DESCRIPTION |
| GFV-DES |
10- Key Audio/Video
Entrance Panel |
| GFA-DES |
10- Key Audio-Only
Entrance Panel |
Entrance Panel Modular Components:
Use these part numbers for ordering
an entrance panel with an exact number of call buttons.
See product brochure or
instructions, or contact
Technical Support for assistance. Please refer to the GF
QuikSpec page for online assistance with specifying the correct
components for
your system. To view an entry panel component
matrix, click here.
| Model |
Description |
|
GF-HID |
Panel with Embedded HID Prox reader and
Wiegand output |
|
GF-HID-I |
Panel with Embedded HID iClass reader and
Wiegand output |
|
GF-VA |
Video Module |
|
GF-VP |
Video Module Panel |
|
GF-NS/A |
Digital LCD Display Module |
|
GF-NSP |
LCD Display Module Panel |
|
GF-10K |
10- Key Module |
|
GF-10KP |
10-Key Module Panel |
|
GF-DA/B |
Audio Module |
|
GF-DP |
Audio Module Panel |
| GF-SW |
Call Switch Module |
| GF-1P |
1- Call button Panel |
| GF-2P |
2-Call button Panel |
| GF-3P |
3-Call button Panel |
| GF-4P |
4-Call button Panel |
| GF-BP |
Blank Panel |
| GF-AD |
Address Module |
| GF-AP |
Address Panel |
| GF-2F |
2-module front frame |
| GF-3F |
3-module front frame |
| GF-2B |
2-module back box |
| GF-3B |
3-module back box |
| GF-102H |
2 Module Rain Hood (1H x 2V) |
| GF102HB |
2 Module Surface Mount Rain Hood (1H x
2V) |
| GF-103H |
3 Module Mount Rain Hood (1H x 3V) |
| GF-103HB |
3 Module Surface Mount Rain Hood (1H x
3V) |
| GF-202H |
4 Module Mount Rain Hood (2H x 2V) |
| GF-202H |
4 Module Surface Mount Rain Hood (2H x
2V) |
| GF-203H |
6 Module Mount Rain Hood (2H x 3V) |
| GF-203HB |
6 Module Surface Mount Rain Hood (2H x
3V) |
Additional Equipment Required:
| MODEL |
DESCRIPTION |
| GF-1MD |
Inside monitor/handset
station with door
release for systems without a concierge station or panic call
feature
(1 or 2 per apartment, max 250 monitors per system) |
| GF-1D |
Audio handset with door
release for systems without a concierge station or panic call
feature
(1 or 2 per apartment, max 250 total stations per system, audio and
video combined) |
| GF-1MDK |
Inside monitor/handset
station with door
release for systems with a concierge station or panic call
feature
(1 or 2 per apartment, max 250 monitors per system) |
| GF-1DK |
Audio handset with door
release for systems with a concierge station or panic call feature
(1 or 2 per apartment, max 250 total stations per system, audio and
video combined) |
| GF-BC |
Audio Bus Control Unit (1 per
system) |
| GF-VBC/A |
Video Bus Control Unit for
systems with a concierge station(1 per
system) |
| GFW-VBC |
Long distance/high
capacity video control unit (Max. 2 per system) |
| GF-MK |
Concierge Station
Max two per system. Requires use of:
GF-1DK or GF-1MDK Tennant stations
GF-DS/B Audio module
GF-VBC/A Video Bus control unit |
| GF-4Z |
4-Monitor Video
Distribution Adaptor (1 per 4 monitors) |
| PS-2410LC |
Power supply (1 per GF-BC,
1 per GF-VBC(or GF-VBC/A),
1 if GF-NS's are included in system ) |
Additional Optional Equipment :
| MODEL |
DESCRIPTION |
| GFW-S |
Desk stand for GF-MK |
| MCW-S |
Desk stand for GF-1MD |
| W-DIN11 |
Din Rail Mounting Bracket (1 per GF-BC,
GF-VBC, GF-VBC/A, GF-4Z) |
| GF-C |
Connecting Wire (optional, for large
entrance direct-selection panels with audio module installed in center of
panel.) |
| GFK-PS |
Panic Call Switch |
| MAW-B |
External Light Relay |
| RY-24L |
Form "C" door release relay |
| GF-OP2 |
2 panel postal lock |
| GF-OP3 |
3 panel postal lock |
Specifications |
| Power Source |
24V DC, 0.7A
Max. (30mA in standby) Use PS-2410LC only. |
| Power Supply |
PS-2410LC for
each type of adaptor. (One each for GF-BC, GF-VBC/A, GFW-VBC. On
additional GF-VBC/A if two monitors are included per tenant.) |
| Current
Consumption |
GF-BC: 0.7A,
30mA in standby
GF-VBC/A: 0.95A, 20mA in standby
GF-NS: 80mA (continuous) |
| Station Capacity |
Maximum 250
total tenant addresses with 10- key digital calling. Max 100 stations
when using individual tenant call buttons. |
| Entrance Stations |
Max. 5
(audio/video or audio-only) |
| Apartment Station |
Max. two
stations per apartment, intermixable (or less for larger systems. Max.150 GF-1MD's per
system) |
| Max. stations
per trunk line |
50 GF-1D's
25 GF-1MD's (Either loop wired or using GF-4Z's) |
| Trunk Lines |
6 Video trunks from GF-VBC/A
Any number of audio trunks from junction point |
| Talk Path |
Single channel with privacy |
| Calling Tones |
Electronic ring
tone from entrance station(s)
Differentiated ring tone from individual doorbell |
| Door Release Contact |
4A at 24V
AC/DC (EL, EL terminals on GF-DA/A or GF-DA/B, dry closure) |
| Wiring |
2-wire common
bus wiring from Entrances to GF-BC
2-wire common
bus wiring from Entrances to GF-VBC/A
2-wire common bus wiring from GF-VBC/A to GF-1MD's
2-wire common bus wiring from GF-BC to GF-1MD's or GF-1D's |
| Wire |
Use Aiphone wire
#872002 for Audio Pair. 2 conductor,
solid copper, Non-shielded, polyethylene insulation, 20 AWG.
Use Aiphone wire #871802 for Audio Pair. 2 conductor,
solid copper, PE insulation, FPLR, 18 AWG.
NOTE: Proper operation or warranty for the system is not guaranteed
with wire other than specified. |
| Distance |
GF-BC to
Junction Point: 16' with 20AWG
GF-VBC/A to Entrance Stn: 330' with 18AWG
GF-BC & GF-VBC/A to PS-2410LC: 16' with 20AWG
GF-VBC/A to farthest GF-1MD: 500' with 18AWG (w/1 monitor);
330'
with 18AWG (w/2 monitors)
GF-BC to farthest Audio Only Entrance(s): 980' with 20AWG
GF-BC to farthest Handset station: 980' with 20AWG
Total cumulative audio wire distance must not exceed 7,920' per
system with 20AWG |
|