AP-M Series:
High-Power 
Intercom
 

AP-M High Power, Open Voice Intercom

 

Features (Back to top)

 

Expanded master with high-powered 10W output for high noise areas.
One or two masters can be included. 
Hands free reply from remote area.
AP-1M, AP-5M, or AP-10M master stations available, desk or wall mount.
Use 8 ohm horn speaker for maximum output, or wall or ceiling speaker sub stations.
Subs call master with LED and electronic tone.
Built-in power supply.
Special master units available for expanded capacity -- Up to 50 stations.
Use QuikSpec to design this system.

 

 

Product Photos (Back to top)

Click picture to view larger image. Use the "Back" button on your browser to return to this page.

Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
AP-5M AP-10M AS-3A AS-3N
Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page. Click picture to view larger image. Use the "Back" button on your browser to return to this page.
LS-NVP/B LE-SS LE-SSR AH-108

 

Specifications  (Back to top)

Power Source 110 ~ 125V AC, 50/60Hz.  Plug into wall outlet.
Consumption 45W. 6W (standby)
Communication

Tone & LED, 15 seconds.
Select station and press Talk/Listen button.
Group call to max. 5 subs.
Max. 10W transmit, adjustable.
300mW receive, adjustable.

Wiring 1 twisted pair per sub, homerun. (Use Aiphone #822202.)
5 wires (3 pairs) between masters for master-to-master communication, plus a pair for each sub.
Distance 500' with 22AWG,  1200' with 18AWG (Master to sub).

 

 

Click here to QuikSpec this system
Use QuikSpec to design an AP-M High Powered system  (Back to top)

 

Literature Available (Back to top)

AP-M Installation Manual
AP-M Operation Manual
AP-M/MP-S Sub Station Spec Sheet
Horn Speaker Spec Sheet
AP-10MS Spec Sheet
AP-10MS Instructions
AP-nAS/C Instructions
BA-1P Spec Sheet
BA-1P Instructions
LS-NVP/B Spec Sheet
LS-NVP/B Instructions
LE-SSV Vandal resistant Sub Station with built-in pinhole camera
LE-SS/LE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Spec Sheet
LE-SS/LE-SSR 2-Gang Stainless Steel, Vandal and Weather Resistant Subs Instr
LE-SS-1G 1-Gang Stainless Steel, Vandal and Weather Resistant Sub Instr
SBX-2G Surface Mount Box for LE-SS & LE-SSR Spec Sheet
 

Modifications Available (Back to top)

Aiphone has always recognized that there are features and functions that our products don't have. In response we've created a manual detailing the in-field customization of our units to do some of  the more frequently requested functions. Called the "Modification Manual"  and now in it's fifteenth year, it has been an invaluable source of knowledge for in field technicians. It is available free of charge for the first time here.

All modification are in PDF format and are broken down into 5 levels, based on their difficulty:

Level 1 - Easy - Wire Connection Only
Level 2 - Easy/Moderate - Component Connection to External points
Level 3 - Moderate - Removal and replacement of internal Components
Level 4 - Moderate/Hard - Internal connection or component addition
Level 5 - Hard - Circuit Creation and Internal Addition

Please note that modifying a unit will not void it's warranty unless while doing the modification you damage the unit. Aiphone is not liable for any damaged caused during modification. Modifications should only be performed by a person with the skills and knowledge necessary to successfully complete the modification.

MODIFICATION: DIFFICULTY LEVEL:
Zone Paging with the AP-M System 1 - Easy
External signaling when a sub station calls in 2 - Easy/moderate
LED monitoring indicator on a sub station 5 - Hard
Using an LE series sub station with the AP-M system 4 - Moderate/hard
Extending the LED timing circuit for a longer period of time 4 - Moderate/hard
Increase the incoming call tone volume from a sub 4 - Moderate/hard
Long distance communication (2500' max.) 4 - Moderate/hard
Call tone activation while in monitoring mode 4 - Moderate/hard
Lamp memory on a single-master AP-M system 3 - Moderate
Using UL Listed power supplies 4 - Moderate/hard
Background music through an AP-M system 4 - Moderate/hard
Tape recorder output 5 - Hard
Increase communication volume between master stations 4 - Moderate/hard
Increase receive volume at master station  3 - Moderate

For additional information contact your Aiphone Representative.
For best results use Internet Explorer or Netscape Navigator 4.0 or above.
For comments about this site: webmaster@aiphone.com
Copyright 2002 by Aiphone Corporation - All rights reserved.

Got  questions?

Use "QuikFAQ" to get instant answers!